Détails sur le produit:
Conditions de paiement et expédition:
|
| Matériel: | Acier | Force de fil: | 1770MPA |
|---|---|---|---|
| Diamètre du fil: | 3/4mm | Ouverture de maillage: | 103 mm x 180 mm |
| Mettre en évidence: | TECCO System G65/4 wire mesh,metal wire mesh for TECCO System,G65/4 TECCO System components |
||
The TECCO system G65/4 consists of TECCO mesh G65/4, anchors, and anchor bearing plate, border and suture ropes and net connection clips.
The TECCO Mesh G65/4 is made of high-tensile steel wire 4.0mm ( tensile strength ≥1770Mpa), with the mesh size 83*138mm (+/-0.5mm), with mesh ends knotted, roll wide can be 2.9m-4.5m, roll length 10m-30m.
And with anchors the TECCO Mesh G65/4 covers over the slope tension and firmly. The TECCO erosion blanket is firmly fixed to slopes and features a finer mesh to ensure that small rocks can be held in place in addition to large boulders.
Standard Specification of TECCO System G65/4
Wire diameter:3mm
Hole Inscribed circle diameter: 65mm(+/- 5%) Mesh Size: 83*138mm(+/- 5mm)
Roll Size: 3.5m x 10m/20m/30m Mesh Ends Knotted
Standard Specification of TECCO System G65/3
Wire diameter:4mm
Hole Inscribed circle diameter: 65mm (+/- 5%) Mesh Size: 83*143mm (+/- 5mm)
Roll Size: 3.5m x 10m/20m/30m Mesh Ends Knotted
Anchors
Deformed steel bar anchor diameter: 25mm or 28mm
Length:2m -5m
Anchor bearing plate: 320mm x 170/180mm
Rope
Border rope diameter: 12mm or 16mm
Seaming rope diameter: 8mm
Benefits
Compared with other active protection systems:
Only 60%-80% cost compare with the traditional wire rope system.
Fast and easy installation
![]()
![]()
high-tensile tecco mesh Component
• Tecco mesh.Main part of the High-Tensile Steel high-tensile tecco mesh for Slope Rock Fall Protection system system. It is made of high tensile steel wire and have excellent corrosion resistance • performance. The 1770 N/m2tensile strength supply maximum protection for the slope and people.
• Steel anchor.The steel anchor is made of deformed steel bar with 25 mm diameter, it is mainly used to fix the high-tensile tecco mesh onto the rock or soil slopes. It can supply the whole stability to the slope and tecco mesh.
• Claw type spike plate.The claw type spike plate is commonly used with nails to fasten the high-tensile tecco mesh onto the slope firmly. The claw design make the spike plate a more stable and firm structure.
• Soil or rock nails.Used with claw type spike plate to fix the high-tensile tecco mesh onto the mountain. High tensile strength and solid structure make it be long service life and good condition.
• Clips.The clips are used to connect the neighbor high-tensile tecco mesh firmly. It is an alternative to the sewing rope and the connection is commonly without overlap.
• Sewing rope.It is used for connecting the neighbor tecco meshes. And the connection is commonly have overlaps. It can be used to replace the clips.
• Boundary rope.Pass through the high-tensile tecco mesh and then be fixed onto the anchor for high-tensile tecco mesh and system stability.
| Technical Data Sheet CE European Technical Approval ETA-17/0118 | |
| Technical data | 65/3 |
| Wire diameter | 3.0mm |
| Steel quality | high-tensile steel wire |
| Tensile resistance of a wire | 12.5kN |
| Mesh shape | Rhomboid |
| Tensile strength of steel wire | >1770 N/mm² |
| Tensile strength steel wire mesh | min.150kN/m |
| Diagonal | 83×143mm(+/-3%) |
| Mesh width | 65mm(+/-3%) |
| Compound protection | Zn/AI coating of steel wires |
| Compound of corrosion protection | 95% Zn / 5% AI |
| Coating | min.150g/m² |
| ≤5% dark brown rust in salt spray test according to EN ISO 9227 | 1700 hours(ETA-17/0118) |
| Roll with | 2m,2.5m,3m,3.5m,4m,customized |
| Roll length | 10m,20m,30m,(as per site requirement) |
| Mesh edges | Mesh ebds knotted(customized) |
Benefits of high-tensile tecco mesh
Rockfall protection nets offer several benefits over other types of rockfall protection measures. First and foremost, they are cost-effective and require minimal maintenance. Unlike other rockfall protection measures such as barriers and fences, rockfall protection nets do not require frequent replacement, repair, or repainting. Additionally, they can be installed quickly, minimizing disruption to the surrounding area.
The high-tensile high-tensile tecco mesh is also woven in a diamond structure and quite convenient to store. It's easy and quick to unroll and install the high-tensile tecco mesh with the help of mechanized technology, which largely save you time on the project.
The correct system installation process of high-tensile tecco mesh
Stage I :Clearing and leveling of the slope according to design requirements
Stage II : Staking out all important points on a slope (nail-distance according to design value, drilling points, etc.)
Stage III : Drilling works and nails installation
Stage IV : Choose anchor points in depressions or cutting and preparing of dells around nail heads
Stage V :Drainage or other required elements installation
Stage VI : Erosion control mat TECMAT® installation for enhanced greening if soil material can be flushed away
Stage VII : Unrolling and TECCO® mesh fixation
Stage VIII :Connecting individual sheets of meshes with connection clips
Stage IX : Rope anchors with flexible head and boundary ropes installation
Stage X : System pretensioning according to design value using a torque wrench
Stage XI : Slope greening (seeding, hydroseeding, etc.)
Personne à contacter: Mr. Devin Wang